Diamond Plan

Bloomfield Cooling & Heating’s Priority Plus Diamond Plan

Our Diamond maintenance plan includes $100 per year in Friendly Credits with combined coverage and an annual heating and cooling tune-up for maximum efficiency. There is no diagnostic fee for service calls, plus repair or replacement of the parts listed at bottom of page are no cost to you.

Our Priority Plus Diamond Plan includes:

Furnace
1. Test carbon monoxide levels.
2. Clean and adjust burners and inspect heat exchanger.
3. Check thermostat operation.
4. Lubricate all motors, bearings, fans and circulator pumps where possible.
5. Clean pilot assembly.
6. Install standard one-inch filters.
7. Test and adjust operation of safety and operating controls.
8. Inspect flue pipe and gas valve.
9. Check blower motor (and belt if applicable).
10. Test and tighten all wiring and connections.
11. Turn exposed dampers to heating position if marked
12. Inform customer of equipment condition & recommend necessary repairs.

Hot Water Boiler
1. Test carbon monoxide levels.
2. Check thermostat operation.
3. Check electrical connections.
4. Lubricate pump bearings and motors.
5. Clean combustion chamber.
6. Check pilot assembly.
7. Check zone valves.
8. Check all safeties.
9. Check flue pipe and draft.
10. Check expansion tank.
11. Check aquastat/relay.
12. Check water regulator.

Steam boiler
1. Test carbon monoxide levels.
2. Check thermostat operation.
3. Check electrical connections.
4. Clean combustion chamber.
5. Check pilot assembly.
6. Check all safeties.
7. Check flue pipe and draft.
8. Check and drain low-water cutoff.
9. Check gauge glass.
10. Check and adjust water level.
11. Check auto feed (if applicable).

Master cooling tune-up and safety check
1. Lubricate all moving parts, such as blower motor and condenser fan.
2. Check suction line temperature and pressure.
3. Evaluate condition of air filters. Clean or replace with standard 1″ filters.
4. Test temperature drop between return and supply air.
5. Flush condensate drain to protect against overflow.
6. Clean the outdoor condenser coil.
7. Check blower motor (and belt if applicable).
8. Adjust blower speed.
9. Safety test on all controls for proper operation.
10. Meter voltage and amperage in all motors. Test for worn bearings.
11. Test operation and condition of compressor contacts.
12. Inspect, start and run capacitors and relays for bulges, rust and leaks.
13. Tighten and safety test all wires and connections.
14. Clean and adjust thermostat/mercury bulb.
15. Inform customer of equipment condition, recommend necessary repairs.

Master heating tune-up and safety check of furnace
1. Test carbon monoxide levels.
2. Clean and adjust burners and inspect heat exchanger.
3. Check thermostat operation.
4. Lubricate all motors, bearings, fans and circulator pumps where possible.
5. Clean pilot assembly.
6. Install standard one-inch filters.
7. Test and adjust operation of safety and operating controls
8. Inspect flue pipe and gas valve.
9. Check blower motor (and belt if applicable).
10. Test and tighten all wiring and connections.
11. Turn exposed dampers to heating position if marked
12. Inform customer of equipment condition & recommend necessary repairs.

The following parts will be replaced at no charge with combined coverage:

Gas heating system controls
Combination fan/limit control, electronic ignition control, fan control, fuses, high or low limit control, ignition leads, aqua stat, thermostat.
 
Furnace systems/air handler
Blower, blower bearings, blower belts, blower circuit board, blower motor, blower pulley; blower shaft, blower wheel
Motor capacitor, motor and assembly
Draft inducer; condensate pump; fan relay.
 
Boiler
Circulator pump; zone valves; expansion tank; low water cutoff
 
Burner parts
Burner orifice and burner tubes
Flame sensor, igniter
Gas stop valve, gas valve
Low voltage transformer
Pilot assembly, pilot burner, pilot orifice, pilot valve
Pressure regulator, pressure switch
Thermocouple, accumulator, metering device
Condenser fan blades, potential relay, condenser fan motor
Rain shield
Condensate pump, refrigerant contactor
Reversing valve, crankcase heater
Run capacitor
Defrost board, thermostat, defrost sensor
Starting capacitor, fan belt, starting relay, fan relay
Time delay board
High pressure control, low pressure control
TXV valve
Transformer

Use your friendly credits toward the purchase of the following equipment.

EZ-Flex air cleaner; LPB or SBP humidifiers; heat recovery units; complete a/c systems; gas furnaces; replacement condensing units; carrier thermostats; zoning systems; carrier infinity control; carbon monoxide detector; standby electric emergency generators.